Engineering
Engineering
5 min read
5 min read
Understanding IPC/WHMA-A-620: What Class 3 Really Means
Understanding IPC/WHMA-A-620: What Class 3 Really Means
By TRS International Manufacturing
By TRS International Manufacturing

IPC/WHMA-A-620 is the joint standard from IPC and the Wire Harness Manufacturers Association that defines acceptability requirements for cable and wire harness assemblies. It is the document our production floor lives by, so here is a plain-language tour.
What the standard covers
A-620 defines acceptable and defect conditions across every operation in harness building: wire preparation, crimping, soldering, shield termination, molding, labeling, and testing. Each criterion is specified per class, so the same crimp can be acceptable for a Class 2 product and a defect for Class 3.
Living the standard, not framing it
We maintain an in-house certified IPC trainer, which means workmanship criteria are taught, reinforced, and audited on our own floor continuously, not once a year by a visiting auditor. Operators are certified to the current revision, and acceptance criteria are built into our inspection steps at each stage of the build.
For mission-critical programs, ask any prospective supplier which A-620 class they build to and how their operators stay current. The answers separate the shops that own the standard from the ones that borrow it.
Related: Quality & Certifications
IPC/WHMA-A-620 is the joint standard from IPC and the Wire Harness Manufacturers Association that defines acceptability requirements for cable and wire harness assemblies. It is the document our production floor lives by, so here is a plain-language tour.
What the standard covers
A-620 defines acceptable and defect conditions across every operation in harness building: wire preparation, crimping, soldering, shield termination, molding, labeling, and testing. Each criterion is specified per class, so the same crimp can be acceptable for a Class 2 product and a defect for Class 3.
Living the standard, not framing it
We maintain an in-house certified IPC trainer, which means workmanship criteria are taught, reinforced, and audited on our own floor continuously, not once a year by a visiting auditor. Operators are certified to the current revision, and acceptance criteria are built into our inspection steps at each stage of the build.
For mission-critical programs, ask any prospective supplier which A-620 class they build to and how their operators stay current. The answers separate the shops that own the standard from the ones that borrow it.
Related: Quality & Certifications
