RF antenna equipment connected with RF coaxial cable assemblies

RF, coaxial, and triaxial cable assemblies

RF, coaxial, and triaxial cable assemblies

Cables that carry radio signals between antennas, radios, radar, and cameras with as little signal loss as possible.

Cables that carry radio signals between antennas, radios, radar, and cameras with as little signal loss as possible.

What is an RF cable assembly?

What is an RF cable assembly?

An RF cable assembly is a length of coaxial cable with a connector on each end, built to move high-frequency signals without distorting them. Coaxial cable wraps a center conductor in insulation and a metal shield. Triaxial cable adds a second, insulated shield for extra protection from electrical noise, which is why broadcast cameras and sensitive test equipment use it.

An RF cable assembly is a length of coaxial cable with a connector on each end, built to move high-frequency signals without distorting them. Coaxial cable wraps a center conductor in insulation and a metal shield. Triaxial cable adds a second, insulated shield for extra protection from electrical noise, which is why broadcast cameras and sensitive test equipment use it.

Why build quality matters

Why build quality matters

At radio frequencies, small build variations become lost signal. Impedance mismatches, gaps in the shield, and inconsistent termination all add loss that is hard to trace once the assembly is installed. We build to your frequency range and loss budget, hold termination to setup checks, and test every assembly before it ships.

At radio frequencies, small build variations become lost signal. Impedance mismatches, gaps in the shield, and inconsistent termination all add loss that is hard to trace once the assembly is installed. We build to your frequency range and loss budget, hold termination to setup checks, and test every assembly before it ships.

Low-Loss Transmission

Low-Loss Transmission

Coaxial & Triaxial

Coaxial & Triaxial

100% Continuity Testing

100% Continuity Testing

AS9100D

AS9100D

RF coaxial cable assembly with BNC connectors

How we build RF assemblies.

How we build RF assemblies.

Termination as a controlled process

Termination as a controlled process

Contact position, dielectric trim, and ferrule crimp are held to setup checks, because small variations show up as loss.

Contact position, dielectric trim, and ferrule crimp are held to setup checks, because small variations show up as loss.

Cable and connector guidance

Cable and connector guidance

Help choosing the cable and connector series that match your frequency range and loss budget.

Help choosing the cable and connector series that match your frequency range and loss budget.

Documented performance

Documented performance

Test results are recorded for each assembly, so you have data on the exact part you installed.

Test results are recorded for each assembly, so you have data on the exact part you installed.

Samples to production lots

Samples to production lots

Engineering samples and production lots built on the same fixtures and process, so performance carries over.

Engineering samples and production lots built on the same fixtures and process, so performance carries over.

Technical details.

Technical details.

For engineers: the key specs at a glance. Send your drawing or spec and we’ll confirm fit.

For engineers: the key specs at a glance. Send your drawing or spec and we’ll confirm fit.

Cable types

Cable types

Coaxial and triaxial cables in low-loss, flexible, and semi-rigid constructions.

Coaxial and triaxial cables in low-loss, flexible, and semi-rigid constructions.

Connector families

Connector families

SMA, SMB, SMC, BNC, TNC, N-Type, MCX, MMCX, triaxial, and other RF connector families.

SMA, SMB, SMC, BNC, TNC, N-Type, MCX, MMCX, triaxial, and other RF connector families.

Frequency range

Frequency range

Application-specific, based on cable and connector selection.

Application-specific, based on cable and connector selection.

Impedance

Impedance

50 Ω and 75 Ω, depending on cable and connector selection.

50 Ω and 75 Ω, depending on cable and connector selection.

Testing

Testing

VSWR and return loss (how much signal reflects back instead of passing through), insertion loss, and continuity, with braid coverage and connector seating inspected on every assembly.

VSWR and return loss (how much signal reflects back instead of passing through), insertion loss, and continuity, with braid coverage and connector seating inspected on every assembly.

Standards & quality

Standards & quality

IPC/WHMA-A-620 workmanship, AS9100D and ISO 9001:2015 quality systems, ITAR registered.

IPC/WHMA-A-620 workmanship, AS9100D and ISO 9001:2015 quality systems, ITAR registered.

Lengths & volumes

Lengths & volumes

Engineering samples through production lots. Custom lengths to your specification, subject to RF performance requirements.

Engineering samples through production lots. Custom lengths to your specification, subject to RF performance requirements.

Documentation

Documentation

Test results recorded for each assembly and kept with the lot.

Test results recorded for each assembly and kept with the lot.

Common questions

Common questions

Do you make prototypes and small quantities?

Do you make prototypes and small quantities?

Do you make prototypes and small quantities?

Yes. Prototype and low-volume builds are a routine part of our work, and the same engineering and inspection discipline applies from the first article onward.

Yes. Prototype and low-volume builds are a routine part of our work, and the same engineering and inspection discipline applies from the first article onward.

What’s the difference between coaxial and triaxial?

What’s the difference between coaxial and triaxial?

What’s the difference between coaxial and triaxial?

Triaxial cable adds a second, insulated shield around a coaxial cable. That extra layer isolates the signal from electrical noise, which is why broadcast cameras and sensitive measurement equipment use it.

Triaxial cable adds a second, insulated shield around a coaxial cable. That extra layer isolates the signal from electrical noise, which is why broadcast cameras and sensitive measurement equipment use it.

What should I send for a quote?

What should I send for a quote?

What should I send for a quote?

Drawings, a wire list, or a sketch, plus a description of the operating environment. For RF assemblies, include the frequency range and loss budget if you have them.

Drawings, a wire list, or a sketch, plus a description of the operating environment. For RF assemblies, include the frequency range and loss budget if you have them.

Can you build to my drawing?

Can you build to my drawing?

Can you build to my drawing?

Yes. We build to your drawings and specifications, and we flag manufacturability concerns before they reach production.

Yes. We build to your drawings and specifications, and we flag manufacturability concerns before they reach production.

Ready to spec an RF, coax, or triax assembly?

Ready to spec an RF, coax, or triax assembly?