Rugged circular connector with spring strain relief on a heavy-duty cable

Ruggedized and harsh-environment assemblies

Ruggedized and harsh-environment assemblies

Cable assemblies sealed and reinforced to keep working through shock, vibration, water, dust, and temperature extremes.

Cable assemblies sealed and reinforced to keep working through shock, vibration, water, dust, and temperature extremes.

What is a ruggedized cable assembly?

What is a ruggedized cable assembly?

A ruggedized cable assembly is built to survive places where ordinary cables fail: outdoors, on moving equipment, around water, or in extreme heat and cold. Tougher jackets, sealed connectors, overmolding, and strain relief protect the cable, and environmental testing proves it before it ships.

A ruggedized cable assembly is built to survive places where ordinary cables fail: outdoors, on moving equipment, around water, or in extreme heat and cold. Tougher jackets, sealed connectors, overmolding, and strain relief protect the cable, and environmental testing proves it before it ships.

Why build quality matters

Why build quality matters

Harsh-environment failures usually start at the weakest point of an assembly: an unsealed backshell, a jacket that cracks in the cold, or strain relief that fatigues under vibration. We choose jacket materials, sealing, overmolding, and strain relief for your actual operating conditions, then verify them with environmental testing in-house.

Harsh-environment failures usually start at the weakest point of an assembly: an unsealed backshell, a jacket that cracks in the cold, or strain relief that fatigues under vibration. We choose jacket materials, sealing, overmolding, and strain relief for your actual operating conditions, then verify them with environmental testing in-house.

Environmental Testing

Environmental Testing

Environmental Sealing

Environmental Sealing

Strain Relief Design

Strain Relief Design

AS9100D

AS9100D

Jacketed cable harness with two MIL-spec circular connectors

How we build ruggedized assemblies.

How we build ruggedized assemblies.

Materials chosen for the environment

Materials chosen for the environment

Jacket, seal, and connector materials are selected together for temperature, fluids, abrasion, and UV.

Jacket, seal, and connector materials are selected together for temperature, fluids, abrasion, and UV.

In-house sealing and overmolding

Sealing and overmolding in-house

Overmold tooling developed for your connector and cable, from prototype quantities to production runs.

Overmold tooling developed for your connector and cable, from prototype quantities to production runs.

Built for shock and vibration

Sealed for your environment

Strain relief, backshells, and cable routing are chosen to hold up under vibration, flexing, and impact.

Washdown, outdoor, and immersion requirements drive compound selection and seal design from the start.

Tested to your spec

Tested to your spec

Temperature, humidity, submersion, and pull-force testing done in-house.

Temperature, humidity, submersion, and pull-force testing done in-house.

Technical details.

Technical details.

For engineers: the key specs at a glance. Send your drawing or spec and we’ll confirm fit.

For engineers: the key specs at a glance. Send your drawing or spec and we’ll confirm fit.

Environmental testing

Environmental testing

Temperature, humidity, submersion, and pull-force testing in-house.

Temperature, humidity, submersion, and pull-force testing in-house.

Sealing

Sealing

Overmolding and sealed connectors for washdown, outdoor use, and immersion.

Overmolding and sealed connectors for washdown, outdoor use, and immersion.

Jackets & connectors

Jackets & connectors

Polyurethane (PUR), TPE, and fluoropolymer (FEP/PTFE) jackets. MIL-DTL-38999 circular, M8/M12 industrial, and sealed connector options.

Polyurethane (PUR), TPE, and fluoropolymer (FEP/PTFE) jackets. MIL-DTL-38999 circular, M8/M12 industrial, and sealed connector options.

Temperature range

Temperature range

Tested to ATPD-2167 (Environmental Test Methods, M1 Tank Program), from -60 °F to +250 °F.

Tested to ATPD-2167 (Environmental Test Methods, M1 Tank Program), from -60 °F to +250 °F.

Ingress rating

Ingress rating

IP67 and IP68 options, depending on assembly design and application requirements. Submersion testing available.

IP67 and IP68 options, depending on assembly design and application requirements. Submersion testing available.

Quality

Quality

IPC/WHMA-A-620 workmanship, AS9100D and ISO 9001:2015 quality systems, ITAR registered.

IPC/WHMA-A-620 workmanship, AS9100D and ISO 9001:2015 quality systems.

Volumes

Volumes

Prototype through production.

Prototype through production.

Documentation

Documentation

Test results documented against the lot.

Test results documented against the lot.

Common questions

Common questions

What’s the difference between ruggedized and overmolded?

What’s the difference between ruggedized and overmolded?

What’s the difference between ruggedized and overmolded?

Overmolding is one way we ruggedize a cable. A ruggedized assembly can also use tougher jackets, sealed connectors, and extra strain relief, depending on what the environment demands.

Overmolding is one way we ruggedize a cable. A ruggedized assembly can also use tougher jackets, sealed connectors, and extra strain relief, depending on what the environment demands.

Can you test to our environmental spec?

Can you test to our environmental spec?

Can you test to our environmental spec?

Yes. Temperature, humidity, submersion, and pull-force testing are done in-house, with methods and limits agreed before we quote.

Yes. Temperature, humidity, submersion, and pull-force testing are done in-house, with methods and limits agreed before we quote.

Can you build to my drawing?

Can you build to my drawing?

Can you build to my drawing?

Yes. We build to your drawings and specifications, and we flag manufacturability concerns before they reach production.

Yes. We build to your drawings and specifications, and we flag manufacturability concerns before they reach production.

What should I send for a quote?

What should I send for a quote?

What should I send for a quote?

Drawings, a wire list, or a sketch, plus a description of the operating environment. An engineer reviews it and follows up with any questions.

Drawings, a wire list, or a sketch, plus a description of the operating environment. An engineer reviews it and follows up with any questions.

Ready to spec a ruggedized assembly?

Ready to spec a ruggedized assembly?