EMI/RFI-shielded cable assemblies
EMI/RFI-shielded cable assemblies
Cable assemblies with metal shielding that keeps electrical noise out of sensitive signals and stops noisy power lines from disturbing nearby equipment.
Cable assemblies with metal shielding that keeps electrical noise out of sensitive signals and stops noisy power lines from disturbing nearby equipment.
What is an EMI/RFI-shielded cable assembly?
What is an EMI/RFI-shielded cable assembly?
EMI and RFI stand for electromagnetic and radio-frequency interference: electrical noise from motors, radios, and power lines that can corrupt signals. A shielded cable assembly wraps the conductors in metal braid or foil and connects that shield to ground, so the noise drains away instead of reaching the signal.
EMI and RFI stand for electromagnetic and radio-frequency interference: electrical noise from motors, radios, and power lines that can corrupt signals. A shielded cable assembly wraps the conductors in metal braid or foil and connects that shield to ground, so the noise drains away instead of reaching the signal.
Why build quality matters
Why build quality matters
Shielding only works as well as its termination. A gap in braid coverage, a poorly bonded backshell, or a drain wire left too long can let interference in. We use braid, foil, and hybrid shield systems with defined grounding schemes and 360-degree terminations, matched to your frequency range and installation.
Shielding only works as well as its termination. A gap in braid coverage, a poorly bonded backshell, or a drain wire left too long can let interference in. We use braid, foil, and hybrid shield systems with defined grounding schemes and 360-degree terminations, matched to your frequency range and installation.
360° Terminations
360° Terminations
Braid & Foil Shielding
Braid & Foil Shielding
100% Continuity Testing
100% Continuity Testing
AS9100D
AS9100D

Where shielded assemblies are used.
Where shielded assemblies are used.
Industrial Automation & Robotics
Industrial Automation & Robotics
Shielding that keeps drive and switching noise out of control signals.
Shielding that keeps drive and switching noise out of control signals.
Aerospace & Defense
Aerospace & Defense
Shielded assemblies for dense avionics bays.
Shielded assemblies for dense avionics bays.
Automotive & Transportation
Automotive & Transportation
Shielding that keeps power-electronics noise out of signal paths.
Shielding that keeps power electronics out of signal paths.
How we build shielded assemblies.
How we build shielded assemblies.
Grounding defined up front
Grounding defined up front
Grounding schemes are set during design review, so shield drains and backshells are terminated the same way on every build.
Grounding schemes are set during design review, so shield drains and backshells are terminated the same way on every build.
Requirements set up front
Requirements set up front
Shield type and coverage are chosen from your frequency range, noise sources, and flex requirements.
Shield type and coverage are chosen from your frequency range, noise sources, and flex requirements.
Repeatable across lots
Repeatable across lots
Controlled materials and setups keep performance consistent across the production run.
Controlled materials and setups keep performance consistent across the production run.
Your lengths, your pinouts
Your lengths, your pinouts
Built to the exact length, pinout, and connector combination your system needs.
Built to the exact length, pinout, and connector combination your system needs.
Technical details.
Technical details.
For engineers: the key specs at a glance. Send your drawing or spec and we’ll confirm fit.
For engineers: the key specs at a glance. Send your drawing or spec and we’ll confirm fit.
Shield types
Shield types
Braid, foil, and hybrid shield systems.
Braid, foil, and hybrid shield systems.
Terminations
Terminations
360-degree terminations that bond the shield around the full connector.
360-degree terminations that bond the shield around the full connector.
Grounding
Grounding
Grounding schemes defined at design review.
Grounding schemes defined at design review.
Testing
Testing
Continuity, insulation resistance, and Hipot on every assembly, with braid coverage and connector seating inspected.
Continuity, insulation resistance, and Hipot on every assembly, with braid coverage and connector seating inspected.
Shielding effectiveness
Shielding effectiveness
Application-specific EMI/RFI protection using foil, braided, or combined shielding with proper shield termination.
Application-specific EMI/RFI protection using foil, braided, or combined shielding with proper shield termination.
Frequency range
Frequency range
Tailored to your EMI/RFI requirements. Shielding is matched to the specified frequency band.
Tailored to your EMI/RFI requirements. Shielding performance verified over the specified frequency band.
Quality
Quality
IPC/WHMA-A-620 workmanship, AS9100D and ISO 9001:2015 quality systems, ITAR registered.
IPC/WHMA-A-620 workmanship, AS9100D and ISO 9001:2015 quality systems.
Volumes
Volumes
Prototype through production.
Prototype through production.
Common questions
Common questions
Braid or foil shielding?
Braid or foil shielding?
Braid or foil shielding?
Foil covers the conductors completely and works well at high frequencies. Braid is stronger, more flexible, and better at lower frequencies. Many assemblies use both, chosen from your frequency range, noise sources, and flex requirements.
Foil covers the conductors completely and works well at high frequencies. Braid is stronger, more flexible, and better at lower frequencies. Many assemblies use both, chosen from your frequency range, noise sources, and flex requirements.
Can you build to my drawing?
Can you build to my drawing?
Can you build to my drawing?
Yes. We build to your drawings and specifications, and we flag manufacturability concerns before they reach production.
Yes. We build to your drawings and specifications, and we flag manufacturability concerns before they reach production.
Do you make prototypes and small quantities?
Do you make prototypes and small quantities?
Do you make prototypes and small quantities?
Yes. Prototype and low-volume builds are a routine part of our work, and the same engineering and inspection discipline applies from the first article onward.
Yes. Prototype and low-volume builds are a routine part of our work, and the same engineering and inspection discipline applies from the first article onward.
What should I send for a quote?
What should I send for a quote?
What should I send for a quote?
Drawings, a wire list, or a sketch, plus a description of the operating environment. An engineer reviews it and follows up with any questions.
Drawings, a wire list, or a sketch, plus a description of the operating environment. An engineer reviews it and follows up with any questions.